6430 Excursion-Trac™ Temperature Monitoring & Data Logger Kit -- TM-6430
6430 Excursion-Trac™ Temperature Monitoring & Data Logger Kit -- TM-6430
6430 Excursion-Trac™ Temperature Monitoring & Data Logger Kit -- side
6430 Temp-Monitor-&-Data-Logger - TM-6430 -- Back-View
6430 Temp-Monitor-&-Data-Logger - TM-6430 -- side-view

Excursion-Trac™ Temperature Monitoring & Data Logger Kit

For Monitoring & Logging of Temperatures
SKU:
TM-6430

A data logging thermometer for logging the most recent temperature observations (525,600…memory can be cleared). This calibrated logger has user-defined time intervals, downloads data to any USB stick, and meets current CDC requirements.

$159.00

Cool Cube™ 08 at Frozen Temps

A laboratory qualified system that utilizes PCM technology to keep product -50 to -15°C for 60+ hours w/o the need for electricity or dry ice. Ideal for extended transportation/storage of valuable frozen product, & to have as a power outage backup.

Cool Cube™ 08 at Refrigerated Temps

A laboratory qualified system that utilizes PCM technology to keep product 2-8°C for 76+ hours without the need for electricity, ice or buffering material. Ideal for off-site vaccinations, long-term transportation and power outage backup.

The Excursion-Trac™ Temperature Monitoring & Data Logger Kit (TM-6430) is a data logging thermometer for logging the most recent temperature observations. This calibrated logger has user-defined time intervals (1-minute to 24-hours), downloads data to any USB stick, and meets current CDC requirements making it ideal for monitoring temperatures while storing/transporting vaccines or other important samples. The data logging feature logs the most recent 525,600 data points, although the memory can be cleared and reset. Base unit, probe, certificate, flip-open stand, wall mounting, Velcro®, magnetic strips, batteries, and universal adapter included.

Technology & Features

tech1 TM-6430 magnifying
tech2 TM-6430-40

Meets current CDC requirements for vaccine storage and monitoring (CDC Toolkit – January 2018).

Data is transferred from thermometer to computer using any USB flash drive. No software needed.

Probe bottle (filled with nontoxic GRAS glycol) insulates sensor from momentary temperature changes.

Additional Features

  • Ten-foot micro-cable permits refrigerator doors to close on it.
  • Rolling memory structure, maintains most recent 525,600 temperature observations.
  • Smart-Alarm™ features a visual/audible alarm that continues to alarm even if the unit returns to non-alarm conditions.
  • Memory can be cleared on unit after downloading data to USB stick.
  • Hassle-free retrieval of data – unit can remain in use while downloading and analyzing data.
  • Status indicators – Low battery, memory full, USB data transfer and active alarm state.
  • User-defined data logging interval of one observation/minute to one observation/24 hours.
  • High-accuracy of ±0.25°C with a resolution of 0.01.
  • Multi-point calibration on an individually-numbered certificate assures accuracy.
vfc-compliant

Dimensions & Specs

Base Unit: 2¾” x 4¼” x ¾”
Weight: 5 oz.
Temp Range: -50 to 70°C (-58 to 158°F)

TM-6430 dims

SEAMLESS ACCESSORY



This monitoring device pairs well with a Cool Cube™ PCM cooler. Although the cooler is so consistent and reliable, it is always good practice to keep monitoring temperature sensitive product even when on-the-go.

TM-seamless
TM-easy logger

EASY TO USE



Simple buttons with an easy to understand display make this the go-to product for temperature monitoring simplicity. No special docking stations or software needed to transfer data to a computer (PC or Mac).

HIGHLY REPUTABLE



Beginning with spot measuring in 1978, through the evolution of live Wi-Fi today, Traceable® specializes in condition monitoring in various applications (fridges/freezers, storerooms, research, blood banks, coolers, and more).

TM-reputable
have-questions-plus-number-2

Relevant Literature

Instructional Videos

AC Adapter

Suppressor

Date & Time

Setting °C/°F

Log Interval

Min/Max

Review Data

Downloading

Event History

Alarms

Error Codes

Clearing Memory

have-questions-plus-number-2

FAQs

Search FAQs


Data Logger Specific FAQ

The unit must be plugged in with the power cord to download data. If it still doesn’t work, try another flash drive.
Plug the base unit in using the AC adaptor. Insert USB stick/flash drive into unit’s USB port. Wait one minute. Remove USB stick/flash drive. (the data will be available in a .CSV file on the USB stick/flash drive)
No. Downloadable data (if applicable) is saved under a .CSV format and can be opened in any table structured program (such as Excel).
Excursion-Trac™ devices have a rolling memory structure that stores the most recent 525,600 temperature observations (it will over-write data). Memory-Loc™ devices have a permanent memory structure that stores 1,051,200 temperature observations (it will NOT over-write data and cannot be cleared when full).
Slide the MEM VIEW switch to the ON position and press the ADVANCE button.
The TM-6430/1 is indefinitely. When set at a 1-minute interval, it will start to over-write old data after 1 year (but log data indefinitely). The TM-6440/1 is 2 years when set at a 1-minute interval. Increasing the interval will provide longer a longer data life.
Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred, as well as when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts, and flashing LCD segments. Data for up to 10 different alarm events can be retrieved with the most current event viewable on the display.
Slide the MEM VIEW switch to the ON position and press the CLEAR SILENCE ALM button.
Yes the probes are calibrated to a specific port.
No. Each probe is calibrated to a specific device and port. Probes have stickers identifying the serial number of the device it is calibrated to, as well as the port it is calibrated to.
Yes

Load More



General Temp Monitoring FAQs

Calibration

Devices are recalibrated by Control Company (the manufacturer). Detailed instructions and a recalibration form can be found on our website. Click Here
New units come with a calibration due date of 2 years from the date of manufacture. However, inventorying such products sometimes cuts into this time period weeks or months. We guarantee a calibration due date of at least 1 year past the purchase date.

Load More


Data

Plug the base unit in using the AC adaptor. Insert USB stick/flash drive into unit’s USB port. Wait one minute. Remove USB stick/flash drive. (the data will be available in a .CSV file on the USB stick/flash drive)

Load More


Definitions

Device that logs and records data over a period of time in relation to its environment or application.
Digital Data Logger
How close to being correct it is. The CDC recommends digital data loggers have an accuracy of +/-.5° C (+/-1° F) or better.
Documentation of a multi-point calibration done on a corresponding unit. Assures accuracy from a ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It has traceability measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement.

Load More


Display

The significant digits displayed beyond a whole number.
Visual and audible indicators which signal continuously until acknowledged, even if the parameter returns to the non-alarm range.
If the temperature of the environment is within the thermometers’ or hygrometers’ measuring range, this error will occur if the probe is disconnected or damaged.
Check the batteries, they may need replacing. If still receiving errors after battery replacement, remove the batteries, press all the buttons-one at a time, and put the batteries back in.
Minimum and maximum temperatures of a desired range. Readings above or below the set values will trigger an alarm.
Measurement readings recorded as the minimum (lowest or min) value achieved and the maximum (highest or max) value achieved since being turned on.

Load More


Probes

Yes the probes are calibrated to a specific port.
No. Each probe is calibrated to a specific device and port. Probes have stickers identifying the serial number of the device it is calibrated to, as well as the port it is calibrated to.
Probe bottles are filled with non-toxic glycol solution, which is GRAS (generally recognizes as safe) by the FDA.
30-60 minutes from room temp.

Load More


Settings

See the instructions or watch the video on each product page.
These values are readings only, and are not programmable. 

Load More



Purchasing Related FAQs

Credit Cards

Yes, the major ones.
It can take as little as one hour to condition the PCM panels, and as little as 2 minutes to pack it out. See User Guide for complete instructions.

Load More


Ordering

Order thru GSA or Amazon websites, or directly from this website. For larger orders or for a formal quote please contact us (866-469-6019).

Load More


Pricing

Yes. Discounts start at 10 or more of the same model.
Direct (call or email), on Amazon (direct) or thru a valued distributor (Evolve, Grainger, Illinois Medical Services, Control Solutions, etc.).

Load More


Shipping

Usually 1 to 2 business days depending on stock.
ESTIMATE: Small CC = $16 | Medium CC = $20 | Large CC = $50 | TM = $12 (actual prices may vary depending on location of the customer and exact product shipped).

Load More